Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
---|---|---|---|---|---|---|---|
M1 | Source address | ||||||
M2 | ZZ | Target address | |||||
M3 | PB = B5h | Vaillant command | |||||
M4 | SB = 12h | Unknown command [ping ?] | |||||
M5 | NN = 02h | Length of data | |||||
M6 | xx | ? | |||||
M7 | yy | ? | |||||
M8 | CRC | ||||||
S1 | ACK | ||||||
S2 | NN = 00h | Length of data | |||||
S3 | CRC | ||||||
M9 | ACK | ||||||
M10 | SYN |
The following cases were observed:
Heater Controller (Master 10h) → Firing Automat 1 (Slave 08h):
(xx = 00h, yy = 00h) hot water circulating pump is off
(xx = 00h, yy = 64h) hot water circulating pump is on
Firing Automat 1 (Master 03h) → Pump 1 (Slave 64h):
(xx = 02h, yy = 00h) internal pump is off
(xx = 02h, yy = 64h) internal pump is on and operating in the service water circuit
(xx = 02h, yy = FEh) internal pump is on and operating in the heating circuit
(xx = 03h, yy = 00h) internal pump is disabled due to error condition (such as water pressure too low)
Firing Automat 1 (Master 03h) → PC/ Modem (Slave 05h):
(xx = 03h, yy = 00h)