Dies ist eine alte Version des Dokuments!
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | |
M2 | ZZ | Target address | | | | | |
M3 | PB = B5h | Vaillant command | | | | | |
M4 | SB = 04h | Get Date/Time | | | | | |
M5 | NN = 01h | Length of data | | | | | |
M6 | 00h | Data Block Identifer | | | | | |
M7 | CRC | | | | | | |
S1 | ACK | | | | | | |
S2 | NN = 0Ah | Length of data | | | | | |
… | | | | | | | |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | |
M2 | ZZ | Target address | | | | | |
M3 | PB = B5h | Vaillant command | | | | | |
M4 | SB = 04h | Get Data Block | | | | | |
M5 | NN = 01h | Length of data | | | | | |
M6 | DB = 00h | Block 00h (Date/Time) | | | | | |
M7 | CRC | | | | | | |
S1 | ACK | | | | | | |
S2 | NN = 0Ah | Length of data | | | | | |
S3 | 00h 01h 02h 03h | DCF77 status: no receiption receiption synchronized data valid | | | BYTE | | |
S4 | ss | Seconds | Sec | 0..59 | BCD | | |
S5 | min | Minutes | Min | 0..59 | BCD | | |
S6 | hh | Hours | Hour | 0..59 | BCD | | |
S7 | dd | Day | | 1..31 | BCD | | |
S8 | mm | Month | | 1..12 | BCD | | |
S9 | ww | Weekday | | 1..7 | BCD | | |
S10 | yy | Year | | 0..99 | BCD | | |
S11 | TA_L | Outside temperature | °C | -50,0 – 50,0 | DATA2b [1/256] | | |
S12 | TA_H |
||||||
S13 | CRC | | | | | | |
M8 | ACK | | | | | | |
M9 | SYN | | | | | | |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | 26h |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 01h | Block 01h | | | | | 01h |
M7 | CRC | | | | | | D8h |
S1 | ACK | | | | | | 00h |
S2 | NN = 09h | Length of data | | | | | 09h |
S3 | tt | set temperature - room: ZZ=26h - service water: ZZ=25h | °C | | char | | 14h |
S4 | | | | | | | 04h, 03h |
S5 | | | | | | | 00h |
S6 | | | | | | | 00h |
S7 | | | | | | | 02h |
S8 | | | | | | | 05h |
S9 | | | | | | | 00h |
S10 | dd | night=0 / day=1 | On/Off | | char | | 00h |
S11 | | | | | | | 00h |
S12 | CRC | | | | | | 2Ch |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address HK1: 26h; WW:25h; ZP:23h | | | | | 26h/25h/23h |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 02h | Block 02h | | | | | 02h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 07h | Length of data | | | | | 07h |
S3 | TB1 | Zeitfenster1 Beginn | 10Min | | char | | |
S4 | TE1 | Zeitfenster1 Ende | 10Min | | char | | |
S5 | TB2 | Zeitfenster2 Beginn | 10Min | | char | | |
S6 | TE2 | Zeitfenster2 Ende | 10Min | | char | | |
S7 | TB3 | Zeitfenster3 Beginn | 10Min | | char | | |
S8 | TE3 | Zeitfenster3 Ende | 10Min | | char | | 03h |
S9 | DAY | char | |||||
S9 | CRC | | | | | | B2h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h 10h |
M2 | ZZ | Target address | | | | | 23h 25h 26 50 EC |
M3 | PB = B5h | Vaillant command | | | | | B5h B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h 04h |
M5 | NN = 01h | Length of data | | | | | 01h 01h |
M6 | DB = 09h | Block 09h | | | | | 09h 09h |
M7 | CRC | | | | | | CEh DAh |
S1 | ACK | | | | | | 00h 00h |
S2 | NN = 0Ah | Length of data | | | | | 0Ah 0Ah |
S3 | |
RaumTemp
|
|
|
char
|
|
14h 37h
|
S4 | |
AbsenkTemp
|
|
|
char
|
|
00h 00h
|
S5 | | Heizkurve * 10 | | | char | | 00h 00h |
S6 | | | | | | | 00h 00h |
S7 | | | | | | | 06h 03h |
S8 | | AT-AbschaltTemp | | | char | | 16h 16h |
S9 | | | | | | | 00h 00h |
S10 | |
MinTempVL
|
|
|
char
|
|
0Fh 0Fh
|
S11 | |
MaxTempVL
|
|
|
char
|
|
4Bh 5Ah
|
S12 | | | | | | | 00h 00h |
S13 | CRC | | | | | | 80h 4Eh |
M8 | ACK | | | | | | 00h 00h |
M9 | SYN | | | | | | AAh AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note | ||||
M1 | | Source address | | | | | 10h | ||||
M2 | ZZ | Target address | | | | | 23h 25h 26 50 EC | ||||
M3 | PB = B5h | Vaillant command | | | | | B5h | ||||
M4 | SB = 04h | Get Data Block | | | | | 04h | ||||
M5 | NN = 01h | Length of data | | | | | 01h | ||||
M6 | DB = 0Dh | Block 0Dh | | | | | 0Dh | ||||
M7 | CRC | | | | | | CAh | ||||
S1 | ACK | | | | | | 00h | ||||
S2 | NN = 05h | Length of data | | | | | 05h | ||||
S3 | VL_TT | flow set temperature | °C | | char | | 00h | ||||
S4 | |||||||||||
S5 | TT_L | Temperature of the service water store (ZZ=25h) Tempeature of flow water (Z=26h) | °C\\ \\ | \\ \\ | \\ DATA2c \\ \\ \\ | \\ \\ | \\ 00h \\ \\ \\ | | S6 | TT_H | ||||||
S7 | R_TT | room set temperature ZZ=26h | °C | | char | | 00h | ||||
S8 | CRC | | | | | | 4Ch | ||||
M8 | ACK | | | | | | 00h | ||||
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 0Fh | Block 0Fh | | | | | 0Fh |
M7 | CRC | | | | | | C7h |
S1 | ACK | | | | | | 00h |
S2 | NN = 0Ah | Length of data | | | | | 0Ah |
S3 | XX = 14h | | | | | | 59h |
S4 | XX = 00h | | | | | | 03h |
S5 | XX = 00h | | | | | | 3Ch |
S6 | XX = 00h | | | | | | 03h |
S7 | XX = 06h | | | | | | 21h |
S8 | XX = 16h | | | | | | FFh |
S9 | XX = 00h | | | | | | 21h |
S10 | XX = 0Fh | | | | | | FFh |
S11 | XX = 4Bh | | | | | | 00h |
S12 | XX = 00h | | | | | | 00h |
S13 | CRC | | | | | | E4h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 10h | Block 10h | | | | | 10h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 0Ah | Length of data | | | | | 0Ah |
S3 | TW1_L | Service-Water Temperatur 1 | °C | | DATA2C | | 50h |
S4 | TW1_H | | | 0Ch |
|||
S5 | TW2_L | Service-Water Temperatur 2 | °C | |
DATA2C
|
|
08h
|
S6 | TW2_H | | | 50h |
|||
S7 | TW3_L | Service-Water Temperatur 3 | °C | |
DATA2C
|
|
07h
|
S8 | TW3_H | | | 03h |
|||
S9 | TD1_L | Tempeartursensor TD1 | °C | DAT2C | |||
S10 | TD1_H | ||||||
S11 | TD2_L | Tempeartursensor TD1 | °C | DATA2C | |||
S12 | TD2_H | ||||||
S10 | CRC | | | | | | B2h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 11h | Block 11h | | | | | 11h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 06h | Length of data | | | | | 06h |
S3 | | | | | | | 50h |
S4 | | | | | | | 0Ch |
S5 | | | | | | | 08h |
S6 | | | | | | | 50h |
S7 | | | | | | | 07h |
S8 | | | | | | | 03h |
S9 | CRC | | | | | | B2h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 12h | Block 12h | | | | | 12h |
M7 | CRC | | | | | | DAh |
S1 | ACK | | | | | | 00h |
S2 | NN = 0Ah | Length of data | | | | | 0Ah |
S3 | | | | | | | 4Bh |
S4 | | | | | | | 00h |
S5 | | | | | | | 00h |
S6 | | | | | | | 67h |
S7 | | | | | | | 0Bh |
S8 | | | | | | | 00h |
S9 | | | | | | | 80h |
S10 | | | | | | | 00h |
S11 | | | | | | | 00h |
S12 | | | | | | | 00h |
S13 | CRC | | | | | | 0Bh |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | 25h |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 17h | Block 17h | | | | | 17h |
M7 | CRC | | | | | | DAh |
S1 | ACK | | | | | | 00h |
S2 | NN = 01h | Length of data | | | | | 0Ah |
S3 | AA | Service time for Service water |
OnOff
|
|
char
|
|
|
S4 | CRC | | | | | | |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
===== Block 18h – Heating-Lead-Temperature for HK2 (Mixer) incl. Raising-Temp.
(Kessel-Soll für HK2 incl. Temperaturüberhöhung )
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | 50h |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 17h | Block 17h | | | | | 18h |
M7 | CRC | | | | | | E7h |
S1 | ACK | | | | | | 00h |
S2 | NN = 01h | Length of data | | | | | 06h |
S3 | HLT_KH2_L | Heizkessel-Solltemperatur für Versorgung HK2 mit Offset „Temperaturüberhöhung“ | | | data2b | | 20h |
S4 | HLT_HK2_H | | | | 1fh |
||
S5 | unknown - always 00h | 00h | |||||
S6 | HK2_T_L | Vorlauftemperatur HK2 | data2c | 9dh | |||
S7 | HK2_T_H | 01h | |||||
S8 | unknown | 15h or 13h | |||||
S9 | CRC | 86h | |||||
M8 | ACK | | | | | 00h |
|
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 11h | Block 11h | | | | | 11h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 05h | Length of data | | | | | 05h |
S3 | CC | Collector temperature | °C | | char | | |
S4 | DD | unkown | | | | | 00h |
S5 | EE | heater source 0: off 1: solar 2: heater | | | char | | |
S6 | FF | Storage level | % | | char | | Entspricht der Füllstandsanzeige im IDLE-Display der Steuerung |
S7 | GG | Power | % | | char | | Entpsricht Balken- anzeige im Display |
S8 | CRC | | | | | | |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 12h | Block 11h | | | | | 11h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 03h | Length of data | | | | | 05h |
S3 | OO | unkown | | | | | 00h |
S4 | PP | unkown | | | | | 04h |
S5 | | unkown | | | | | 07h |
S6 | CRC | | | | | | 24h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 25h | Block 25h | | | | | 25h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 02h | Length of data | | | | | 02h |
S3 | PP | unknown | 07h |
||||
S4 | | unkown | | | | | 03h |
S5 | CRC | | | | | | D8h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | QQ = 30h | Source address | | | | | |
M2 | ZZ = 26h | Target address | | | | | |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 26h | Block 26h | | | | | 26h |
M7 | CRC | | | | | | |
S1 | ACK | | | | | | |
S2 | NN = 07h | Length of data | | | | | |
S3 | ? | | | | |
||
S4 | MO | Current mode of operation: 00h=heating disabled, 02h=day, 03h=day, 04h=night | | byte | | |
|
S5 | ? | | |||||
S6 | RS | Target room temperature | °C | data1c | |||
S7 | ? | ||||||
S8 | RC_L | Current room temperature (corrected by offset value) | °C | data2c | |||
S9 | RC_H | ||||||
S10 | CRC | | | | | | |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
The current room temperature in this frame (bytes S8 and S9, RC_L and RC_H) is unreliable and should not be used! Instead, use the data from the frame (qq=30h, zz=26h, pb=B5h, sb=05h, nn=05h, first data byte 3Ch).
Also note that the byte S6 has been found to be missing if the target room temperature is set to 22.0°C. It is unclear whether this is intentional or a bug.
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 28h | Block 28h | | | | | 28h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 03h | Length of data | | | | | 05h |
S3 | SE_L | Solarertrag | kWh | | word | | |
S4 | PP | | | |
|||
S5 | | unkown | | | | | 00h |
S6 | CRC | | | | | | 24h |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |
Master/ Slave Byte-No. | Abbrev. | Description | Unit | Range | Type/ [Res.] | Repl. Value | Note |
M1 | | Source address | | | | | 10h |
M2 | ZZ | Target address | | | | | ECh |
M3 | PB = B5h | Vaillant command | | | | | B5h |
M4 | SB = 04h | Get Data Block | | | | | 04h |
M5 | NN = 01h | Length of data | | | | | 01h |
M6 | DB = 36h | Block 36h | | | | | 36h |
M7 | CRC | | | | | | D9h |
S1 | ACK | | | | | | 00h |
S2 | NN = 01h | Length of data | | | | | 01h |
S3 | | unkown | | | | | 00h |
S4 | CRC | | | | | | 9Bh |
M8 | ACK | | | | | | 00h |
M9 | SYN | | | | | | AAh |