Benutzer-Werkzeuge

Webseiten-Werkzeuge


ebus:serviceb505

Dies ist eine alte Version des Dokuments!


B5h 05h – Burner Operational Data

This Broadcast informs about the operational data of the burner control unit. It seems to be a Vaillant specific variant of Service 08h 01h.


Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ

Source address











M2

ZZ = FEh

Target address











M3

PB = B5h

Vaillant command











M4

SB = 05h

Burner Operational Data?











M5

NN = 02h

Length of data











M6

xx = 04h

xx = 29h











unknown

M7

yy = 00h











unknown

M8

CRC













M9

SYN













Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ

Source address









VRS620

M2

ZZ = FEh

Target address











M3

PB = B5h

Vaillant command











M4

SB = 05h

Burner Operational Data











M5

NN = 04h

Length of data











M6

xx = 27h

(unknown)









unknown

M7



Bit0 = BW_load





BYTE



00h, 01h

This bit is active when service water is loaded.

M8

VT

Lead water temperature

°C

0-89

CHAR

5A h

Vorlauftemperatur IST HK1

VF1-Fühler

M9



Bit0 = BW_load





BYTE



00h, 01h

This bit seems to be synchronous to M7 Bit0.

M10

CRC













M11

SYN












.M6 xx=2Dh gesehen, dabei haben die Daten M7 - M9 aber andere Werte gehabt.

Block 36h – Unknown


Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ

Source address









10h

M2

ZZ

Target address









FEh

M3

PB = B5h

Vaillant command









B5h

M4

SB = 05h

Get Data Block









04h

M5

NN = 02h

Length of data









01h

M6

DB = 06h

Block 06h









06h

M7

NN

On/OFF??

Zubegin von Einmaliger Speicherladung mit 01h und zum Ende 00h

00h / 01h

M8

CRC











D9h

Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ

Source address









VRS620

M2

ZZ = FEh

Target address











M3

PB = B5h

Vaillant command











M4

SB = 05h

Burner Operational Data











M5

NN = 08h

Length of data











M6

xx = 2Bh

(unknown)









unknown

M7









gesehen 0Fh

M8



gesehen 01h

M9

gesehen 00h
M10 gesehen 00h
M11 gesehen 00h
M12 gesehen 00h
M13 gesehen 80h

M14

CRC













M15

SYN












Block 3C - VR 81 remote control unit for VRC 430(f)/470(f)


Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ = 30h

Source address









30h

M2

ZZ = 26h

Target address









26h

M3

PB = B5h

Vaillant command









B5h

M4

SB = 05h

Get Data Block









05h

M5

NN = 05h

Length of data









05h

M6

DB = 3Ch

Block 3Ch









3Ch
M7RC_A_LCurrent room temperature (not corrected by offset value) data2c
M8RC_A_H
M9RC_B_LCurrent room temperature (corrected by offset value) data2c
M10RC_B_H

M11

CRC











D9h
M12ACK

This frame can be used to determine the current room temperature reliably. The target room temperature and the current heating status (off, day, night) can be found in the frame (qq=30h, zz=26h, pb=B5h, sb=04, nn=01, first data byte 26h).


ebus/serviceb505.1444851790.txt.gz · Zuletzt geändert: 2015/10/14 19:43 von admin