Benutzer-Werkzeuge

Webseiten-Werkzeuge


ebus:serviceb509

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen gezeigt.

Link zu der Vergleichsansicht

Beide Seiten, vorherige Überarbeitung Vorherige Überarbeitung
ebus:serviceb509 [2015/10/14 14:48]
admin
ebus:serviceb509 [2015/10/14 15:08] (aktuell)
Zeile 5: Zeile 5:
 ==== Block 0Dh - Read device configuration or status parameters ==== ==== Block 0Dh - Read device configuration or status parameters ====
  
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | +^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ 
- \\ M1 \\  \\ QQ \\  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M1 |QQ |Source address |  |  |  |  |  | 
- \\ M2 \\  \\ ZZ \\  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ ECh, 10h (room controller), 15h (burner) \\ +|M2 |ZZ |Target address |  |  |  |  |ECh, 10h (room controller), 15h (burner) | 
- \\ M3 \\  \\ PB = B5h \\  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M3 |PB = B5h |Vaillant command |  |  |  |  |  | 
- \\ M4 \\  \\ SB = 09h \\  \\ Get or Set Device Configuration or Status \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M4 |SB = 09h |Get or Set Device Configuration or Status |  |  |  |  |  | 
- \\ M5 \\  \\ NN = 03h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M5 |NN = 03h |Length of data |  |  |  |  |  | 
- \\ M6 \\  \\ DB = 0Dh \\  \\ Block 0Dh: Read device configuration or parameters \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M6 |DB = 0Dh |Block 0Dh: Read device configuration or parameters |  |  |  |  |  | 
- \\ M7 \\  \\ P1 = xx1h \\  \\ Low byte of parameter address \\  \\ Sensor: \\ 00h: water basin 1] \\ 01h: water basin 2 \\ 02h: water basin 3 \\ 03h: Collector 1 \\ 04h: Collector 2 \\ 05h: Gain \\  \\  \\ °C \\ °C \\ °C \\ °C \\ °C \\ °C \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ For Solar devices: \\  \\  \\ SP1 \\ SP2 \\ SP3 \\ Kol1 \\ Kol2 / VF1[1] \\ Ertrag \\  \\ For other devices there are different address values (see below) \\  \\   \\ +|M7 |P1 = xx1h |Low byte of parameter address \\  \\ Sensor: \\ 00h: water basin 1] \\ 01h: water basin 2 \\ 02h: water basin 3 \\ 03h: Collector 1 \\ 04h: Collector 2 \\ 05h: Gain | \\ °C \\ °C \\ °C \\ °C \\ °C \\ °C |  |  |  |For Solar devices: \\  \\  \\ SP1 \\ SP2 \\ SP3 \\ Kol1 \\ Kol2 / VF1[1] \\ Ertrag \\  \\ For other devices there are different address values (see below) \\  \\   | 
- \\ M8 \\  \\ P2 = xx2h \\  \\ High byte of parameter address \\  \\ Parameter 2 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ High byte of parameter address \\ +|M8 |P2 = xx2h |High byte of parameter address \\  \\ Parameter 2 |  |  |  |  |High byte of parameter address | 
- \\ M9 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M9 |CRC |  |  |  |  |  |  | 
- \\ S1 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S1 |ACK |  |  |  |  |  |  | 
- \\ S2 \\  \\ NN = 03h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ Response depends on requested parameter type (see below) \\ +|S2 |NN = 03h |Length of data |  |  |  |  |Response depends on requested parameter type (see below) | 
- \\ S3 \\  \\ D_L \\  \\ Sensor Value \\ |  \\   \\ |  \\   \\  \\ DATA2c \\  \\ [1/16] \\ |  \\   \\ |  \\   \\ +|S3 |D_L |Sensor Value |  |  |DATA2c \\  \\ [1/16] |  |  | 
- \\ S4 \\  \\ D_H \\ | ::: | ::: | ::: | ::: | ::: | ::: | +|S4 |D_H | ::: | ::: | ::: | ::: | ::: | ::: | 
- \\ S5 \\  \\ 00h \\ AAH \\  \\ sensor connected \\ no sensor connected \\ |  \\   \\ |  \\   \\  \\ CHAR \\ |  \\   \\ |  \\   \\ +|S5 |00h \\ AAH |sensor connected \\ no sensor connected |  |  |CHAR |  |  | 
- \\ S6 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S6 |CRC |  |  |  |  |  |  | 
- \\ M10 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M10 |ACK |  |  |  |  |  |  | 
- \\ M11 \\  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |+|M11 |SYN |  |  |  |  |  |  |
  
 [1] auroMATIC 620 [1] auroMATIC 620
Zeile 28: Zeile 28:
 **The 0Dh command seems to be implemented by all Vaillant eBus devices**. **vrDialog ** application includes a file vrDIALOG810.mdb, that contains MS Access database used internally by vrDialog. This database can be accessed in order to read different configuration parameters for different supported types of Vaillant eBus devices. For example, using this database for VRT360, it the following command can be executed: **The 0Dh command seems to be implemented by all Vaillant eBus devices**. **vrDialog ** application includes a file vrDIALOG810.mdb, that contains MS Access database used internally by vrDialog. This database can be accessed in order to read different configuration parameters for different supported types of Vaillant eBus devices. For example, using this database for VRT360, it the following command can be executed:
  
-''select [[http://ebus.webhop.org/twiki/bin/view.pl/EBus/SymList|SymList]].name, type, address from +''select %%SymList%%.name, type, address from 
-[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/ShowData?topicparent=EBus.ServiceB509;nowysiwyg=0|ShowData]] [[http://ebus.webhop.org/twiki/bin/view.pl/EBus/SymList|SymList]] where +%%ShowData%%%%SymList%% where 
-[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/ShowData?topicparent=EBus.ServiceB509;nowysiwyg=0|ShowData]] .page ='VRT360' and [[http://ebus.webhop.org/twiki/bin/view.pl/EBus/SymList|SymList]].id = +%%ShowData%%.page ='VRT360' and %%SymList%%.id = 
-[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/ShowData?topicparent=EBus.ServiceB509;nowysiwyg=0|ShowData]] .varid and accesslevel <'' 50 order by +%%ShowData%%.varid and accesslevel <'' 50 order by 
-[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/ShowData?topicparent=EBus.ServiceB509;nowysiwyg=0|ShowData]] .sortid=+%%ShowData%%.sortid
  
 This results in: This results in:
  
-^[[http://ebus.webhop.org/twiki/bin/view.pl/EBus/ServiceB509?sortcol=0;table=1;up=0#sorted_table| +^Name ^Type ^Address| 
-Name +|%%RaumtemperaturIst%% |Temperatursensor|15| 
- +|%%ActualRoomTempSetpoint%% |TIte|87| 
-</font> ]]^[[http://ebus.webhop.org/twiki/bin/view.pl/EBus/ServiceB509?sortcol=1;table=1;up=0#sorted_table| +|%%StatusDcf%% |%%DcfState%% |38| 
-Type +|%%IsInQuickVeto%% |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/OnOff?topicparent=EBus.ServiceB509;nowysiwyg=0|OnOff]] |49| 
- +|%%QuickVetoTemp%% |TIte|50| 
-</font> ]]^[[http://ebus.webhop.org/twiki/bin/view.pl/EBus/ServiceB509?sortcol=2;table=1;up=0#sorted_table| +|%%IsInSavingsFunction%% |%%OnOff%% |44| 
-Address +|%%SavingsFunctionTime%% |%%SaveFunction%% |45| 
- +|%%IsInParty%% |%%OnOff%% |41| 
-</font> ]]+|%%IsInSingleDHWLoadingMode%% |%%OnOff%% |42| 
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/RaumtemperaturIst?topicparent=EBus.ServiceB509;nowysiwyg=0|RaumtemperaturIst]] |Temperatursensor|15| +|%%IsInHoliday%% |uchar|40|
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/ActualRoomTempSetpoint?topicparent=EBus.ServiceB509;nowysiwyg=0|ActualRoomTempSetpoint]] |TIte|87| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/StatusDcf?topicparent=EBus.ServiceB509;nowysiwyg=0|StatusDcf]] |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/DcfState?topicparent=EBus.ServiceB509;nowysiwyg=0|DcfState]] |38| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/IsInQuickVeto?topicparent=EBus.ServiceB509;nowysiwyg=0|IsInQuickVeto]] |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/OnOff?topicparent=EBus.ServiceB509;nowysiwyg=0|OnOff]] |49| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/QuickVetoTemp?topicparent=EBus.ServiceB509;nowysiwyg=0|QuickVetoTemp]] |TIte|50| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/IsInSavingsFunction?topicparent=EBus.ServiceB509;nowysiwyg=0|IsInSavingsFunction]] |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/OnOff?topicparent=EBus.ServiceB509;nowysiwyg=0|OnOff]] |44| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/SavingsFunctionTime?topicparent=EBus.ServiceB509;nowysiwyg=0|SavingsFunctionTime]] |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/SaveFunction?topicparent=EBus.ServiceB509;nowysiwyg=0|SaveFunction]] |45| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/IsInParty?topicparent=EBus.ServiceB509;nowysiwyg=0|IsInParty]] |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/OnOff?topicparent=EBus.ServiceB509;nowysiwyg=0|OnOff]] |41| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/IsInSingleDHWLoadingMode?topicparent=EBus.ServiceB509;nowysiwyg=0|IsInSingleDHWLoadingMode]] |[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/OnOff?topicparent=EBus.ServiceB509;nowysiwyg=0|OnOff]] |42| +
-|[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/IsInHoliday?topicparent=EBus.ServiceB509;nowysiwyg=0|IsInHoliday]] |uchar|40|+
  
 The **Address** column needs to be passed as P1 and P2 parameters to the **0Dh ** command. The **Type** column determines the type of the response from the device. The response length will depend on that (S2 byte in the response). The **Address** column needs to be passed as P1 and P2 parameters to the **0Dh ** command. The **Type** column determines the type of the response from the device. The response length will depend on that (S2 byte in the response).
Zeile 76: Zeile 67:
   * 01 - response temperature high byte. Actual reported temperature is 157h/16 -> 21.43 Celsius   * 01 - response temperature high byte. Actual reported temperature is 157h/16 -> 21.43 Celsius
   * 00 - temperature sensor status - 00h - OK. According to vrDialog810.mdb, sensor status is defined as follows: "struct {Data2c Temperature; State   * 00 - temperature sensor status - 00h - OK. According to vrDialog810.mdb, sensor status is defined as follows: "struct {Data2c Temperature; State
-[[http://ebus.webhop.org/twiki/bin/edit.pl/EBus/SensorState?topicparent=EBus.ServiceB509;nowysiwyg=0|SensorState]] } Sensor state is defined : State "Ok,Short circuit=85,cutoff=170"+%%SensorState%% } Sensor state is defined : State "Ok,Short circuit=85,cutoff=170"
  
 ==== Block 0Eh - Set device configuration ==== ==== Block 0Eh - Set device configuration ====
  
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | +^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ 
- \\ M1 \\  \\ QQ \\  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M1 |QQ |Source address |  |  |  |  |  | 
- \\ M2 \\  \\ ZZ \\  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ ECh, 10h (room controller), 15h (burner) \\ +|M2 |ZZ |Target address |  |  |  |  |ECh, 10h (room controller), 15h (burner) | 
- \\ M3 \\  \\ PB = B5h \\  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M3 |PB = B5h |Vaillant command |  |  |  |  |  | 
- \\ M4 \\  \\ SB = 09h \\  \\ Get or Set Device Configuration or Status \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M4 |SB = 09h |Get or Set Device Configuration or Status |  |  |  |  |  | 
- \\ M5 \\  \\ NN = XXh \\  \\ Length of data, variable depends on type of parameter that is being set \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M5 |NN = XXh |Length of data, variable depends on type of parameter that is being set |  |  |  |  |  | 
- \\ M6 \\  \\ DB = 0Eh \\  \\ Block 0Eh: Set device configuration \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M6 |DB = 0Eh |Block 0Eh: Set device configuration |  |  |  |  |  | 
- \\ M7 \\  \\ P1 = xx1h \\  \\ Low byte of parameter address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |This is low byte of parameter address. It is set in the same way as command 0Dh (above) +|M7 |P1 = xx1h |Low byte of parameter address |  |  |  |  |This is low byte of parameter address. It is set in the same way as command 0Dh (above) | 
-    \\   \\  +|M8 |P2 = xx2h |High byte of parameter address \\  \\ Parameter 2 |  |  |  |  |High byte of parameter address |
- \\ M8 \\  \\ P2 = xx2h \\  \\ High byte of parameter address \\  \\ Parameter 2 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ High byte of parameter address \\ |+
 |M9...MXX| |Data that is being written as device parameter. The length of the data depends on type of variable being modified. The length is the same as the length of data returned from 0Dh command (see above)| | | | | | |M9...MXX| |Data that is being written as device parameter. The length of the data depends on type of variable being modified. The length is the same as the length of data returned from 0Dh command (see above)| | | | | |
- \\ MXX+1 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|MXX+1 |CRC |  |  |  |  |  |  | 
- \\ S1 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S1 |ACK |  |  |  |  |  |  | 
- \\ S2 \\  \\ 00h - length \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S2 |00h - length |  |  |  |  |  |  | 
- \\ S3 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S3 |CRC |  |  |  |  |  |  | 
- \\ MXX+2 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|MXX+2 |ACK |  |  |  |  |  |  | 
- \\ MXX+3 \\  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |+|MXX+3 |SYN |  |  |  |  |  |  |
  
 This command works in a similar way as 0Dh, but instead of returning configuration from the device, it sets device configuration. This command works in a similar way as 0Dh, but instead of returning configuration from the device, it sets device configuration.
Zeile 102: Zeile 92:
 ==== Block 18h - Unknown ==== ==== Block 18h - Unknown ====
  
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | +^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ 
- \\ M1 \\  \\ QQ \\  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 10h \\ +|M1 |QQ |Source address |  |  |  |  |10h | 
- \\ M2 \\  \\ ZZ \\  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 26h \\ +|M2 |ZZ |Target address |  |  |  |  |26h | 
- \\ M3 \\  \\ PB = B5h \\  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ B5h \\ +|M3 |PB = B5h |Vaillant command |  |  |  |  |B5h | 
- \\ M4 \\  \\ SB = 09h \\  \\ Get Solar Data Block \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 09h \\ +|M4 |SB = 09h |Get Solar Data Block |  |  |  |  |09h | 
- \\ M5 \\  \\ NN = 01h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 01h \\ +|M5 |NN = 01h |Length of data |  |  |  |  |01h | 
- \\ M6 \\  \\ DB = 18<sub>h</sub>  \\  |  \\ Block 18h \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 18h \\ +|M6 |DB = 18<sub>h</sub>  \\  |Block 18h |  |  |  |  |18h | 
- \\ M7 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 3Fh \\ +|M7 |CRC |  |  |  |  |  |3Fh | 
- \\ S1 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S1 |ACK |  |  |  |  |  |00h | 
- \\ S2 \\  \\ NN = 0Ah \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 0Ah \\ +|S2 |NN = 0Ah |Length of data |  |  |  |  |0Ah | 
- \\ S3 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S3 |  |  |  |  |  |  |00h | 
- \\ S4 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S4 |  |  |  |  |  |  |00h | 
- \\ S5 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S5 |  |  |  |  |  |  |00h | 
- \\ S6 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S6 |  |  |  |  |  |  |00h | 
- \\ S7 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S7 |  |  |  |  |  |  |00h | 
- \\ S8 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S8 |  |  |  |  |  |  |00h | 
- \\ S9 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S9 |  |  |  |  |  |  |00h | 
- \\ S10 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S10 |  |  |  |  |  |  |00h | 
- \\ S11 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S11 |  |  |  |  |  |  |00h | 
- \\ S12 \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|S12 |  |  |  |  |  |  |00h | 
- \\ S13 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 9Fh \\ +|S13 |CRC |  |  |  |  |  |9Fh | 
- \\ M8 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ 00h \\ +|M8 |ACK |  |  |  |  |  |00h | 
- \\ M9 \\  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ AAh \\ |+|M9 |SYN |  |  |  |  |  |AAh |
  
 \\ \\
  
  
ebus/serviceb509.1444852083.txt.gz · Zuletzt geändert: 2015/10/14 14:48 von admin