ebus:serviceb510

B5h 10h - Operational Data from Room Controller to Burner Control Unit

Master/ Slave Byte-No. Abbrev. Description Unit Range Type/ [Res.] Repl. Value Note
M1 QQ Source address
M2 ZZ Target address
M3 PB = B5h Vaillant command
M4 SB = 10h Operational Data from Room Controller to Burner Control Unit
M5 NN = 09h Length of data
M6 xx1
unknown, always 00h
M7 xx2
unknown, always 00h
M8 LT Lead water target temperature
(Vorlauftemperatur)
°C 0 – 100 DATA1c
M9 ST Service water target temperature °C 0 – 100 DATA1c
M10 xx3
unknown, always FFh
M11 xx4
unknown, always FFh
M12 xx5 = 00h

= 01h
= 04h
= 05h
= 40h
= 41h
= 44h
= 45h
Bits:

01 - if set, means to TURN OFF heating

04 - if set means to TURN OFF service water heating

40 - unknown?
combination of bit values. Each bit means to turn off specific feature, like service water heating. This is used by the room controller to stop the boler from heating (when the temperature is enough), or stop service water heating
M13 xx6
unknown, always FFh
M14 xx7
unknown, always 00h
M15 CRC
S1 ACK
S2 NN = 01h Length of data
S3 zz = 01h (acknowledge ?) unknown
S4 CRC
M16 ACK
M17 SYN