===== B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit ===== | ===== B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit ===== |
| |
| \\ **Master/ Slave Byte-No.** \\ | \\ **Abbrev.** \\ | \\ **Description** \\ | \\ **Unit** \\ | \\ **Range** \\ | \\ **Type/ [Res.]** \\ | \\ **Repl. Value** \\ | \\ **Note** \\ | | ^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ |
| \\ M1 \\ | \\ QQ \\ | \\ Source address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M1 |QQ |Source address | | | | | | |
| \\ M2 \\ | \\ ZZ \\ | \\ Target address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M2 |ZZ |Target address | | | | | | |
| \\ M3 \\ | \\ PB = B5h \\ | \\ Vaillant command \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M3 |PB = B5h |Vaillant command | | | | | | |
| \\ M4 \\ | \\ SB = 11h \\ | \\ Operational Data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M4 |SB = 11h |Operational Data | | | | | | |
| \\ M5 \\ | \\ NN = 01h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M5 |NN = 01h |Length of data | | | | | | |
| \\ M6 \\ | \\ 01h \\ | \\ Block number \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M6 |01h |Block number | | | | | | |
| \\ M7 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M7 |CRC | | | | | | | |
| \\ S1 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |S1 |ACK | | | | | | | |
| \\ S2 \\ | \\ NN = 09h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |S2 |NN = 09h |Length of data | | | | | | |
| \\ S3 \\ | \\ VT \\ | \\ Lead water temperature (Vorlauf-/ Anlagentemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | |S3 |VT |Lead water temperature (Vorlauf-/ Anlagentemperatur) |°C |0 – 100 |DATA1c | | | |
| \\ S4 \\ | \\ NT \\ | \\ Return water temperature (Nachlauftemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | |S4 |NT |Return water temperature (Nachlauftemperatur) |°C |0 – 100 |DATA1c | | | |
| \\ S5 \\ | \\ TA_L \\ | \\ Outside temperature \\ | \\ °C \\ | \\ -50,0 – 50,0 \\ | \\ DATA2b [1/256] \\ | \\ \\ | \\ \\ | | |S5 |TA_L |Outside temperature |°C |-50,0 – 50,0 |DATA2b [1/256] | | | |
| \\ S6 \\ | \\ TA_H \\ | ::: | ::: | ::: | ::: | ::: | ::: | | |S6 |TA_H | ::: | ::: | ::: | ::: | ::: | ::: | |
| \\ S7 \\ | \\ WT \\ | \\ (WW-Auslauftemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | |S7 |WT |(WW-Auslauftemperatur) |°C |0 – 100 |DATA1c | | | |
| \\ S8 \\ | \\ ST \\ | \\ Service water temperature (WW-Speichertemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | |S8 |ST |Service water temperature (WW-Speichertemperatur) |°C |0 – 100 |DATA1c | | | |
| \\ S9 \\ | \\ vv \\ | \\ Bit 0: Heating \\ Bit 1: Service Water \\ | \\ \\ | \\ \\ | \\ BIT \\ | \\ \\ | \\ 0 = OFF \\ \\ 1 = ON \\ | | |S9 |vv |Bit 0: Heating \\ Bit 1: Service Water | | |BIT | |0 = OFF \\ \\ 1 = ON | |
| \\ S10 \\ | \\ xx<sub>1</sub> \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ unknown, always 00h \\ | | |S10 |xx<sub>1</sub> \\ | | | | | |unknown, always 00h | |
| \\ S11 \\ | \\ xx<sub>2</sub> \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ unknown, always FFh \\ | | |S11 |xx<sub>2</sub> \\ | | | | | |unknown, always FFh | |
| \\ S12 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |S12 |CRC | | | | | | | |
| \\ M8 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M8 |ACK | | | | | | | |
| \\ M9 \\ | \\ SYN \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M9 |SYN | | | | | | | |
| |
===== B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit ===== | ===== B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit ===== |
| |
| \\ **Master/ Slave Byte-No.** \\ | \\ **Abbrev.** \\ | \\ **Description** \\ | \\ **Unit** \\ | \\ **Range** \\ | \\ **Type/ [Res.]** \\ | \\ **Repl. Value** \\ | \\ **Note** \\ | | ^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ |
| \\ M1 \\ | \\ QQ \\ | \\ Source address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M1 |QQ |Source address | | | | | | |
| \\ M2 \\ | \\ ZZ \\ | \\ Target address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M2 |ZZ |Target address | | | | | | |
| \\ M3 \\ | \\ PB = B5h \\ | \\ Vaillant command \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M3 |PB = B5h |Vaillant command | | | | | | |
| \\ M4 \\ | \\ SB = 11h \\ | \\ Operational Data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M4 |SB = 11h |Operational Data | | | | | | |
| \\ M5 \\ | \\ NN = 01h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M5 |NN = 01h |Length of data | | | | | | |
| \\ M6 \\ | \\ 02h \\ | \\ Block number \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M6 |02h |Block number | | | | | | |
| \\ M7 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M7 |CRC | | | | | | | |
| \\ S1 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |S1 |ACK | | | | | | | |
| \\ S2 \\ | \\ NN = 05h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |S2 |NN = 05h |Length of data | | | | | | |
| \\ S3 \\ | \\ xx<sub>1</sub> \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ unknown, always 03h \\ | | |S3 |xx<sub>1</sub> \\ | | | | | |unknown, always 03h | |
| \\ S4 \\ | \\ xx<sub>2</sub> \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ unknown, always 3Ch \\ | | |S4 |xx<sub>2</sub> \\ | | | | | |unknown, always 3Ch | |
| \\ S5 \\ | \\ xx<sub>3</sub> \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ unknown, always 96h \\ | | |S5 |xx<sub>3</sub> \\ | | | | | |unknown, always 96h | |
| \\ S6 \\ | \\ xx<sub>4</sub> \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ unknown, always 46h \\ | | |S6 |xx<sub>4</sub> \\ | | | | | |unknown, always 46h | |
| \\ S7 \\ | \\ ST \\ | \\ Service water target temperature \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | |S7 |ST |Service water target temperature |°C |0 – 100 |DATA1c | | | |
| \\ S8 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |S8 |CRC | | | | | | | |
| \\ M8 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M8 |ACK | | | | | | | |
| \\ M9 \\ | \\ SYN \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | |M9 |SYN | | | | | | |
| |
\\ | \\ |
| |
| |