Zeile 1: Zeile 1:
 ===== B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit ===== ===== B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit =====
  
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | +^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ 
- \\ M1 \\  \\ QQ \\  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M1 |QQ |Source address |  |  |  |  |  | 
- \\ M2 \\  \\ ZZ \\  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M2 |ZZ |Target address |  |  |  |  |  | 
- \\ M3 \\  \\ PB = B5h \\  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M3 |PB = B5h |Vaillant command |  |  |  |  |  | 
- \\ M4 \\  \\ SB = 11h \\  \\ Operational Data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M4 |SB = 11h |Operational Data |  |  |  |  |  | 
- \\ M5 \\  \\ NN = 01h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M5 |NN = 01h |Length of data |  |  |  |  |  | 
- \\ M6 \\  \\ 01h \\  \\ Block number \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M6 |01h |Block number |  |  |  |  |  | 
- \\ M7 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M7 |CRC |  |  |  |  |  |  | 
- \\ S1 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S1 |ACK |  |  |  |  |  |  | 
- \\ S2 \\  \\ NN = 09h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S2 |NN = 09h |Length of data |  |  |  |  |  | 
- \\ S3 \\  \\ VT \\  \\ Lead water temperature (Vorlauf-/ Anlagentemperatur) \\  \\ °C \\  \\ 0 – 100 \\  \\ DATA1c \\ |  \\   \\ |  \\   \\ +|S3 |VT |Lead water temperature (Vorlauf-/ Anlagentemperatur) |°C |0 – 100 |DATA1c |  |  | 
- \\ S4 \\  \\ NT \\  \\ Return water temperature (Nachlauftemperatur) \\  \\ °C \\  \\ 0 – 100 \\  \\ DATA1c \\ |  \\   \\ |  \\   \\ +|S4 |NT |Return water temperature (Nachlauftemperatur) |°C |0 – 100 |DATA1c |  |  | 
- \\ S5 \\  \\ TA_L \\  \\ Outside temperature \\  \\ °C \\  \\ -50,0 – 50,0 \\  \\ DATA2b [1/256] \\ |  \\   \\ |  \\   \\ +|S5 |TA_L |Outside temperature |°C |-50,0 – 50,0 |DATA2b [1/256] |  |  | 
- \\ S6 \\  \\ TA_H \\ | ::: | ::: | ::: | ::: | ::: | ::: | +|S6 |TA_H | ::: | ::: | ::: | ::: | ::: | ::: | 
- \\ S7 \\  \\ WT \\  \\ (WW-Auslauftemperatur) \\  \\ °C \\  \\ 0 – 100 \\  \\ DATA1c \\ |  \\   \\ |  \\   \\ +|S7 |WT |(WW-Auslauftemperatur) |°C |0 – 100 |DATA1c |  |  | 
- \\ S8 \\  \\ ST \\  \\ Service water temperature (WW-Speichertemperatur) \\  \\ °C \\  \\ 0 – 100 \\  \\ DATA1c \\ |  \\   \\ |  \\   \\ +|S8 |ST |Service water temperature (WW-Speichertemperatur) |°C |0 – 100 |DATA1c |  |  | 
- \\ S9 \\  \\ vv \\  \\ Bit 0: Heating \\ Bit 1: Service Water \\ |  \\   \\ |  \\   \\  \\ BIT \\ |  \\   \\  \\ 0 = OFF \\  \\ 1 = ON \\ +|S9 |vv |Bit 0: Heating \\ Bit 1: Service Water |  |  |BIT |  |0 = OFF \\  \\ 1 = ON | 
- \\ S10 \\  \\ xx<sub>1</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ unknown, always 00h \\ +|S10 |xx<sub>1</sub>  \\  |  |  |  |  |  |unknown, always 00h | 
- \\ S11 \\  \\ xx<sub>2</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ unknown, always FFh \\ +|S11 |xx<sub>2</sub>  \\  |  |  |  |  |  |unknown, always FFh | 
- \\ S12 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S12 |CRC |  |  |  |  |  |  | 
- \\ M8 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M8 |ACK |  |  |  |  |  |  | 
- \\ M9 \\  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |+|M9 |SYN |  |  |  |  |  |  |
  
 ===== B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit ===== ===== B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit =====
  
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | +^Master/ Slave Byte-No. ^Abbrev. ^Description ^Unit ^Range ^Type/ [Res.] ^Repl. Value ^Note ^ 
- \\ M1 \\  \\ QQ \\  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M1 |QQ |Source address |  |  |  |  |  | 
- \\ M2 \\  \\ ZZ \\  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M2 |ZZ |Target address |  |  |  |  |  | 
- \\ M3 \\  \\ PB = B5h \\  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M3 |PB = B5h |Vaillant command |  |  |  |  |  | 
- \\ M4 \\  \\ SB = 11h \\  \\ Operational Data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M4 |SB = 11h |Operational Data |  |  |  |  |  | 
- \\ M5 \\  \\ NN = 01h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M5 |NN = 01h |Length of data |  |  |  |  |  | 
- \\ M6 \\  \\ 02h \\  \\ Block number \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M6 |02h |Block number |  |  |  |  |  | 
- \\ M7 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M7 |CRC |  |  |  |  |  |  | 
- \\ S1 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S1 |ACK |  |  |  |  |  |  | 
- \\ S2 \\  \\ NN = 05h \\  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S2 |NN = 05h |Length of data |  |  |  |  |  | 
- \\ S3 \\  \\ xx<sub>1</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ unknown, always 03h \\ +|S3 |xx<sub>1</sub>  \\  |  |  |  |  |  |unknown, always 03h | 
- \\ S4 \\  \\ xx<sub>2</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ unknown, always 3Ch \\ +|S4 |xx<sub>2</sub>  \\  |  |  |  |  |  |unknown, always 3Ch | 
- \\ S5 \\  \\ xx<sub>3</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ unknown, always 96h \\ +|S5 |xx<sub>3</sub>  \\  |  |  |  |  |  |unknown, always 96h | 
- \\ S6 \\  \\ xx<sub>4</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\  \\ unknown, always 46h \\ +|S6 |xx<sub>4</sub>  \\  |  |  |  |  |  |unknown, always 46h | 
- \\ S7 \\  \\ ST \\  \\ Service water target temperature \\  \\ °C \\  \\ 0 – 100 \\  \\ DATA1c \\ |  \\   \\ |  \\   \\ +|S7 |ST |Service water target temperature |°C |0 – 100 |DATA1c |  |  | 
- \\ S8 \\  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|S8 |CRC |  |  |  |  |  |  | 
- \\ M8 \\  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ +|M8 |ACK |  |  |  |  |  |  | 
- \\ M9 \\  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |+|M9 |SYN |  |  |  |  |  |
  
 \\ \\
  
  