Benutzer-Werkzeuge

Webseiten-Werkzeuge


ebus:serviceb511

Dies ist eine alte Version des Dokuments!


B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit


Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ

Source address











M2

ZZ

Target address











M3

PB = B5h

Vaillant command











M4

SB = 11h

Operational Data











M5

NN = 01h

Length of data











M6

01h

Block number











M7

CRC













S1

ACK













S2

NN = 09h

Length of data











S3

VT

Lead water temperature (Vorlauf-/ Anlagentemperatur)

°C

0 – 100

DATA1c





S4

NT

Return water temperature (Nachlauftemperatur)

°C

0 – 100

DATA1c





S5

TA_L

Outside temperature

°C

-50,0 – 50,0

DATA2b [1/256]





S6

TA_H

S7

WT

(WW-Auslauftemperatur)

°C

0 – 100

DATA1c





S8

ST

Service water temperature (WW-Speichertemperatur)

°C

0 – 100

DATA1c





S9

vv

Bit 0: Heating
Bit 1: Service Water





BIT



0 = OFF

1 = ON

S10

xx1











unknown, always 00h

S11

xx2











unknown, always FFh

S12

CRC













M8

ACK













M9

SYN












B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit


Master/ Slave Byte-No.

Abbrev.

Description

Unit

Range

Type/ [Res.]

Repl. Value

Note

M1

QQ

Source address











M2

ZZ

Target address











M3

PB = B5h

Vaillant command











M4

SB = 11h

Operational Data











M5

NN = 01h

Length of data











M6

02h

Block number











M7

CRC













S1

ACK













S2

NN = 05h

Length of data











S3

xx1











unknown, always 03h

S4

xx2











unknown, always 3Ch

S5

xx3











unknown, always 96h

S6

xx4











unknown, always 46h

S7

ST

Service water target temperature

°C

0 – 100

DATA1c





S8

CRC













M8

ACK













M9

SYN











ebus/serviceb511.1444852215.txt.gz · Zuletzt geändert: 2015/10/14 19:50 von admin