-===== B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit ===== 
- 
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | 
-|  \\ M1 \\ |  \\ QQ \\ |  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M2 \\ |  \\ ZZ \\ |  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M3 \\ |  \\ PB = B5h \\ |  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M4 \\ |  \\ SB = 11h \\ |  \\ Operational Data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M5 \\ |  \\ NN = 01h \\ |  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M6 \\ |  \\ 01h \\ |  \\ Block number \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M7 \\ |  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ S1 \\ |  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ S2 \\ |  \\ NN = 09h \\ |  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ S3 \\ |  \\ VT \\ |  \\ Lead water temperature (Vorlauf-/ Anlagentemperatur) \\ |  \\ °C \\ |  \\ 0 – 100 \\ |  \\ DATA1c \\ |  \\   \\ |  \\   \\ | 
-|  \\ S4 \\ |  \\ NT \\ |  \\ Return water temperature (Nachlauftemperatur) \\ |  \\ °C \\ |  \\ 0 – 100 \\ |  \\ DATA1c \\ |  \\   \\ |  \\   \\ | 
-|  \\ S5 \\ |  \\ TA_L \\ |  \\ Outside temperature \\ |  \\ °C \\ |  \\ -50,0 – 50,0 \\ |  \\ DATA2b [1/256] \\ |  \\   \\ |  \\   \\ | 
-|  \\ S6 \\ |  \\ TA_H \\ | ::: | ::: | ::: | ::: | ::: | ::: | 
-|  \\ S7 \\ |  \\ WT \\ |  \\ (WW-Auslauftemperatur) \\ |  \\ °C \\ |  \\ 0 – 100 \\ |  \\ DATA1c \\ |  \\   \\ |  \\   \\ | 
-|  \\ S8 \\ |  \\ ST \\ |  \\ Service water temperature (WW-Speichertemperatur) \\ |  \\ °C \\ |  \\ 0 – 100 \\ |  \\ DATA1c \\ |  \\   \\ |  \\   \\ | 
-|  \\ S9 \\ |  \\ vv \\ |  \\ Bit 0: Heating \\ Bit 1: Service Water \\ |  \\   \\ |  \\   \\ |  \\ BIT \\ |  \\   \\ |  \\ 0 = OFF \\  \\ 1 = ON \\ | 
-|  \\ S10 \\ |  \\ xx<sub>1</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\ unknown, always 00h \\ | 
-|  \\ S11 \\ |  \\ xx<sub>2</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\ unknown, always FFh \\ | 
-|  \\ S12 \\ |  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M8 \\ |  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M9 \\ |  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
- 
-===== B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit ===== 
- 
-|  \\ **Master/ Slave Byte-No.**  \\  |  \\ **Abbrev.**  \\  |  \\ **Description** \\  |  \\ **Unit** \\  |  \\ **Range** \\  |  \\ **Type/ [Res.]**  \\  |  \\ **Repl. Value** \\  |  \\ **Note** \\  | 
-|  \\ M1 \\ |  \\ QQ \\ |  \\ Source address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M2 \\ |  \\ ZZ \\ |  \\ Target address \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M3 \\ |  \\ PB = B5h \\ |  \\ Vaillant command \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M4 \\ |  \\ SB = 11h \\ |  \\ Operational Data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M5 \\ |  \\ NN = 01h \\ |  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M6 \\ |  \\ 02h \\ |  \\ Block number \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M7 \\ |  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ S1 \\ |  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ S2 \\ |  \\ NN = 05h \\ |  \\ Length of data \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ S3 \\ |  \\ xx<sub>1</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\ unknown, always 03h \\ | 
-|  \\ S4 \\ |  \\ xx<sub>2</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\ unknown, always 3Ch \\ | 
-|  \\ S5 \\ |  \\ xx<sub>3</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\ unknown, always 96h \\ | 
-|  \\ S6 \\ |  \\ xx<sub>4</sub>  \\  |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\ unknown, always 46h \\ | 
-|  \\ S7 \\ |  \\ ST \\ |  \\ Service water target temperature \\ |  \\ °C \\ |  \\ 0 – 100 \\ |  \\ DATA1c \\ |  \\   \\ |  \\   \\ | 
-|  \\ S8 \\ |  \\ CRC \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M8 \\ |  \\ ACK \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
-|  \\ M9 \\ |  \\ SYN \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ |  \\   \\ | 
- 
-\\ 
- 
  