Hier werden die Unterschiede zwischen zwei Versionen gezeigt.
ebus:serviceb511 [2015/10/14 19:50] admin |
ebus:serviceb511 [2015/10/14 19:59] |
||
---|---|---|---|
Zeile 1: | Zeile 1: | ||
- | ===== B5h 11h 01h - Operational Data of Burner Control Unit to Room Control Unit ===== | ||
- | |||
- | | \\ **Master/ Slave Byte-No.** | ||
- | | \\ M1 \\ | \\ QQ \\ | \\ Source address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M2 \\ | \\ ZZ \\ | \\ Target address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M3 \\ | \\ PB = B5h \\ | \\ Vaillant command \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M4 \\ | \\ SB = 11h \\ | \\ Operational Data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M5 \\ | \\ NN = 01h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M6 \\ | \\ 01h \\ | \\ Block number \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M7 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ S1 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ S2 \\ | \\ NN = 09h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ S3 \\ | \\ VT \\ | \\ Lead water temperature (Vorlauf-/ Anlagentemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | ||
- | | \\ S4 \\ | \\ NT \\ | \\ Return water temperature (Nachlauftemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | ||
- | | \\ S5 \\ | \\ TA_L \\ | \\ Outside temperature \\ | \\ °C \\ | \\ -50,0 – 50,0 \\ | \\ DATA2b [1/256] \\ | \\ \\ | \\ \\ | | ||
- | | \\ S6 \\ | \\ TA_H \\ | ::: | ::: | ::: | ::: | ::: | ::: | | ||
- | | \\ S7 \\ | \\ WT \\ | \\ (WW-Auslauftemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | ||
- | | \\ S8 \\ | \\ ST \\ | \\ Service water temperature (WW-Speichertemperatur) \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | ||
- | | \\ S9 \\ | \\ vv \\ | \\ Bit 0: Heating \\ Bit 1: Service Water \\ | \\ \\ | \\ \\ | \\ BIT \\ | \\ \\ | \\ 0 = OFF \\ \\ 1 = ON \\ | | ||
- | | \\ S10 \\ | \\ xx< | ||
- | | \\ S11 \\ | \\ xx< | ||
- | | \\ S12 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M8 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M9 \\ | \\ SYN \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | |||
- | ===== B5h 11h 02h - Operational Data of Burner Control Unit to Room Control Unit ===== | ||
- | |||
- | | \\ **Master/ Slave Byte-No.** | ||
- | | \\ M1 \\ | \\ QQ \\ | \\ Source address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M2 \\ | \\ ZZ \\ | \\ Target address \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M3 \\ | \\ PB = B5h \\ | \\ Vaillant command \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M4 \\ | \\ SB = 11h \\ | \\ Operational Data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M5 \\ | \\ NN = 01h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M6 \\ | \\ 02h \\ | \\ Block number \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M7 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ S1 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ S2 \\ | \\ NN = 05h \\ | \\ Length of data \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ S3 \\ | \\ xx< | ||
- | | \\ S4 \\ | \\ xx< | ||
- | | \\ S5 \\ | \\ xx< | ||
- | | \\ S6 \\ | \\ xx< | ||
- | | \\ S7 \\ | \\ ST \\ | \\ Service water target temperature \\ | \\ °C \\ | \\ 0 – 100 \\ | \\ DATA1c \\ | \\ \\ | \\ \\ | | ||
- | | \\ S8 \\ | \\ CRC \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M8 \\ | \\ ACK \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | | \\ M9 \\ | \\ SYN \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | \\ \\ | | ||
- | |||
- | \\ | ||
- | |||